Diesel Generators

Acoustic Canopy
SECI     has       developed     a     Special
 Pressurized Acoustic   Canopy  with  an
 outdoor  design  which  shall   also   help 
save   the   cost  of  big   generator   room 
and    other   special  site    requisites   like 
PCC  foundation   etc.  Acoustic    Canopy 
fabricated   out    of   16  SWG   MS   Sheet 
in      Cubical     design   Spain  Canopies 
optionally offer In-build arrangement  for 
rolling in and out with an eye on after sales 
services    facilities,   enforced    lifting 
hooks,     gasketed    sealed      lockable 
doors,  whether  proof  outdoor  type  top, 
spill   tray   and   oil   draining   arrangement,  float  frame   for   AVM   Pads,  cab   illumination,   inspection  lamp   with  plug  and  socket   adopter,  cab   temperature   sensors, two-way  exhaust  diverter,  flexible  fuel   connector,  with   pressuriser  for  the  Engine  Compartment.
Passage   defuser  for  incoming  and 
outgoing  air  with  cage  for extended 
cooling     and      additional      forced 
ventilation  system which all also contributes to Spain stamp of most  efficieant generator performance.   The  canopy  are  Acoustically
treated inside with    mineral  wool/glass 
wool/puff  and  asbestos coating etc. for 
effective  Sound  dampening and special
Noise reducing arrangements.

 
SELECTION CHART for SECI Diesel Generators
Details of typical load which can be connected to the SECI Domestic Models
  15kva 
Single Phase(10.8kw)
20 S 
15kva
3 Phase(10.8kw)
20 S
30 kva 
3 Phase(20kw)
35 G 
40 kva
3 Phase(20kw)
45 G
Applications  Power Consumption (kw)
1. Lighting
60 Watts x 30 Nos.
1.8kw 1.8 kw 1.8kw  1.8kw
2. Fans
50 Watts x 6Nos.
0.3Kw 0.3Kw 0.3Kw 0.3Kw
3. Water Pump
1hp-0.75kw
(0.8 pf) x 1No,
0.75kw  0.75kw  0.75kw  0.75kw 
OR
Water Pump
2hp-1500 Watts
1.5kw-1No.
  1.50kw    1.50kw    1.50kw    1.50kw 
4. Home Appliances
a) Iron 
0.45kw-1No.
 0.45kw  0.45kw 0.45kw 0.45kw
b) Mixer
1kw-1No.
1.00kw 1.00kw  1.00kw  1.00kw 
c) Vacuum Cleaner
1kw-1No.
1.00kw  1.00kw  1.00kw  1.00kw 
d)Washing Machine 
1kw-1No.
1.00kw  1.00kw  1.00kw  1.00kw 
e)Room Heater  1.00kw 1.00kw 1.00kw 1.00kw
f) Personal Computer 
300 Watts x 2 No.
0.60kw  0.60kw  0.60kw  0.60kw 
g) Cooking Range 
5 kw-1No.
5.00kw  5.00kw  5.00kw 5.00kw 
 h) Refrigerator 
125 Watts x 2 Nos.
 0.25kw  0.25kw  0.25kw  0.25kw
i) Air-conditionor
1Ton x 6Nos.
(Single Phase).
12kw  ----- ----- -----
OR
Air-conditioner 
1Ton x 8 Nos.
-----  12kw 12kw 12kw
OR
Air-conditioner 
1.5 Ton x 6 Nos.
(Three Phase).
------  18kw     

This table gives you an idea of the average power requirements in a 5 to 6 bedroom bunglow or apartment. The total load would amount to about 26 kva. Obiously the 30 kva is your ideal choice. it can take care of all your domestic requirements entirely. And with ease. (Remember, you won't ever be using all the lights, fans, air-conditioners and other appliances at the same time ).
 
LOAD CALCULATION  CHART
Details of typical load which can be connected to the SECI Commercial
  15kva 
Single Phase(10.8kw)
20 S 
15kva
3 Phase(10.8kw)
20 S
30 kva 
3 Phase(20kw)
35 G 
40 kva
3 Phase(20kw)
45 G
Applications  Power Consumption (kw)
1. Lighting 
60Watts x 30 Nos.
1.8 kw  1.8 kw  1.8 kw  1.8 kw 
2. Fans 
50Watts x 6 Nos.
0.3kw  0.3kw  0.3kw  0.3kw 
3. Packaged
Air-conditioner
3 Tr x 4 Nos. 
5 Tr x 4 Nos. 
7.5 Tr x 4 Nos. 
12kw 
 

 18kw 

24kw 

12kw 
 

 18kw 

24kw 

12kw 
 

 18kw

24kw 

12kw
 

 18kw 

24kw 

4. Water Pump 
1hp-0.75kw
(0.8 pf) x No.
0.75kw  0.75kw  0.75kw  0.75kw 
5. Lift 
4 Pers. x 1 Nos.
   5kw  5kw  5kw
6. Personal Computer
30 Watts x 5 Nos.
1.5kw  1.5kw  1.5kw  1.5kw 
7. Refrigertor 
125 Watts x 1 No.
0.13kw 0.13kw 0.13kw 0.13kw

In standard commercial establishment, say for instance an office, a posh restaurant or jewellery shop, the power requirements would be about 35 kva . 40 kva SECI would be perfect for such a set up.

Note : Please consult the concerned personal computer manufacture before using the PC with the SECI for ensuring the frequency and voltage regulation. Certain power conditioning equipment may be necessery.
 
Continious Rating kva    7.5  15  22.5   30  40  62.3 70  80  100  125 
 Model   11s1   20s  3k  35G 45G 8k2 91G 65LGT 8SLG SD2 
BHP @ 1600 RPM 15 10  20  28  38  50 70 90  102  140 156 
Current amp  10.5  21  31.5  42   55.5 84 98  111 138  174
Fuel Consumption Lt/Hr 1.8  3.1  5   7   8  13 16  17 22   27
Size cms  92x60 130x50  155x70 180x80  210x85 240x90 250x90 250x90 250x90  260x90
    110  110 120 148 140 160 160 160 160 160
Rec. (A1) Cable
3.5 Core
Sqmm  1x6 1x10 1x6 1x25 1x35 1x50 1x70 1x95 1x95 1x150
Size of Noise-less 
(Only for General Concept)
  122
x70
x140
175
x80
x140
200
x100
x180
 225
x125
x185
255
x130
x205 
300
x135
x205
310
x135
x205
310
x135
x220
225
x150
x220
325
x150
x220

 
Continious Rating  kva 160 180 200 250 300 320 380 500
Model    SB2     SBD  200S  250D  300D  320D   380B   500D
BHP @ 1600 RPM 15  190  230   253   306  375  380 450   604
Current amp 222  250  278  348 415  445   526   695
Fuel Consumption* Lt/Hr 36  41  45   54   63    67  78  107
Size LxBx Bare* cms 300x100 300x100 330x100 330x100 340x100 340x100 350x100 400x135
    160 160 160 160 175 175 175 200
Rec. (A1) Cable 3.5 Core sqmm 1x240 1x300   2x150  2x240  2x300  3x300 2x300 3x240
Size of Noise-less* 
(Only for General Concept)
  335x155
x220
400x160
x220
430x160
x235
430x175
x235
430x175
x250
440x175
x250
440x180
x250
475x210
250

Subject to change due to constant R & D without further notice.